PC-DMIS 2019 R2 Object Library
WriteRegistryBool Method
See Also  Send Topic Feedback | See Object Hierarchy Chart
lpszSection
String value that specifies the section in which the registry entry that you want to modify resides.
lpszEntry
String value that specifies the entry to which you want to write the value.
bValue
Boolean value to write to the registry entry.
bSetVariable
Boolean value that determines whether or not an associated global variable in PC-DMIS gets changed to the value of the third parameter. This parameter only works for registry entries pertaining to feature ID prefixes.
PCDLRN ActiveX DLL > Application Object : WriteRegistryBool Method

Glossary Item Box

Description

Sets a PC-DMIS registry entry to a TRUE or FALSE value.

Syntax

Visual Basic
Public Function WriteRegistryBool( _
   ByVal lpszSection As String, _
   ByVal lpszEntry As String, _
   ByVal bValue As Boolean, _
   ByVal bSetVariable As Boolean _
) As Boolean

Parameters

lpszSection
String value that specifies the section in which the registry entry that you want to modify resides.
lpszEntry
String value that specifies the entry to which you want to write the value.
bValue
Boolean value to write to the registry entry.
bSetVariable
Boolean value that determines whether or not an associated global variable in PC-DMIS gets changed to the value of the third parameter. This parameter only works for registry entries pertaining to feature ID prefixes.

Return Type

Boolean value that determines whether or not the value of the third parameter was successfully written to the registry entry.

Remarks

 

Example

' This code sample turns off PC-DMIS’s start up music:

Dim myapp As New PCDLRN.Application

Set myapp = CreateObject("pcdlrn.application")

myval = myapp.WriteRegistryBool("Option", "TurnOffTheAnnoyingStartupMusic", False, True)