PC-DMIS 2019 R2 Object Library
ControlPoint Object Members
See Also  Overview  Send Topic Feedback | See Object Hierarchy Chart
PCDLRN ActiveX DLL : ControlPoint Object

Glossary Item Box

Public Properties

Public Property Crossings

This defines the number of time the scan crosses the specified boundary before the alterations defined by the crossing point take effect.

Public Property I

This specifies the I component of the interrupt location's IJK vector.

Public Property J

This specifies the J component of the interrupt location's IJK vector.

Public Property K

This specifies the K component of the interrupt location IJK vector.

Public Property PointDensity

This defines the density of points per millimeter the scan shoud take after it encounters the control point.

Public Property PointDensity2Read/Write: Number of Points per MM for control point. Can be less than 1
Public Property Radius

This defines the Radius of circular control point types (Cones, Spheres, Cylinders).

Public Property SpeedRead/Write: Scan Speed Setting for control point
Public Property TypeThis specifies the type of control point.
Public Property X

This specifies the X value of the interrupt XYZ location.

Public Property Y

This specifies the Y component of the interrupt XYZ location.

Public Property Z

This specifies the Z component of the interrupt XYZ location.

See Also

Copyright © 2019. Hexagon Manufacturing Intelligence – Metrology Software, Inc. All Rights Reserved.