Home > Available Help Files > PC-DMIS NC (Numerical Control) > PC-DMIS NC: Introduction > PC-DMIS NCI Differences
Current Help System: PC-DMIS NC (View Core Help)
The following are fundamental differences of PC-DMIS NCI.
Differences from PC-DMIS:
DCC only.
Calibration Tool Location is definable for DCC probe calibration.
Initial rough location of the part must be specified in Machine Coordinates (no manual teach-in).
Differences from PC-DMIS NC:
No export of a measurement path measurement routine (.cnc).
The active work offset has no effect. All motion is generated in machine coordinates and adjusted to match the active work offset.
Only one machine is defined using the NC Gateway server application. The machine must have Machine ID = 1.