Creating a Runout Feature Control Frame Dimension

Runout Feature Control Frame (FCF) dimensions are often used to determine the coaxiality of a selected feature with respect to a selected datum or datums. You must select at least one datum when you create a runout FCF dimension.

There are two types of runout:

In addition, the Feature Control Frame tab in the XactMeasure GD&T dialog box (Insert | Dimension | <dimension>) contains two options buttons, Axial and Radial:

These buttons are discussed in the "Feature Control Frame Tab" topic under "Feature Control Frame Options" and then "Axial and Radial options".

Axial Runout

This type of runout is measured on the end surface of a cylindrical part. The end of the cylinder can be measured as a circle or a plane.

Radial Runout

This type of runout is measured on the cylindrical surface of a bore or shaft.

Single Datums

Both circular and total runout (axial and radial) require at least one datum. 

Two Datums

If the runout type is Radial, then you may specify two datums.

Compound Datums

The datum may also be a compound datum that references two cylinders (such as A-B). If the runout type is Radial, then you may specify two datums.