AskForQ() = FALSE - This parameter requests the system to return the Q() parameter with the scan data. PC-DMIS does not use the Q() scan data. Set this parameter to TRUE if a given server is "hard-wired" to transmit the Q() scan data.
MaxCommandLength - The system uses this parameter as a check by the ScanOnCurve I++ command (any defined path scan) only. The default value is 65500 (64KB).
NonPlanarCircleScan - This parameter forces PC-DMIS to generate the basic Circle scan (ScanOnCircle) instead of the Plane scan (ScanInPlaneEndIsPlane). The default value is TRUE.
NoScan = FALSE - If this parameter is set to TRUE, it prevents the system from setting up the scan parameters. This is an obsolete parameter.
ScanSpeed = 50 - This parameter establishes a default speed for scanning commands.
ScansWillReportIJK = FALSE - If this parameter is set to TRUE, PC-DMIS prompts to include the IJK values in the scan report.
ScansWillReportR = TRUE - If you set this parameter to TRUE, the system prompts to transmit the effective probe radius back for scans.