This registry entry determines how PC-DMIS applies the thickness distance from "DccThickness2Distance". The software applies this distance to Auto Edge Points.
0 - You should use this option (Adjust Theoretical) when the theoretical values need to be adjusted by a thickness because the software performs the measurements on the opposite side of the material.
1 - You should use this option (Adjust Actual) when the software adjusts the measurements by the thickness back to the original theoretical XYZ locations. With this option, it appears that the theoretical and measured values have not been offset, and the target is offset. You still need to modify your target so that PC-DMIS drives to the correct location.
Entry Name: DccThickness2IsActual
Entry Type: Whole Number to specify thickness option. The default value is 0.