The specified tolerance values will be applied to the nominal values according to places after the decimal point.
For example, if you enter a nominal value of 6.250, PC-DMIS sets the + and - tolerances to the DefaultTolerance3 value. If you enter 6.25, PC-DMIS sets the + and - tolerances to the DefaultTolerance2 value.
Entry Name: DefaultTolerance(0-5)
Entry Type: Real number that specifies the tolerance value. The default value is 0.01.
Tolerances Places Key
Tolerance |
|
Decimal Places |
DefaultTolerance0 |
25 |
0 |
DefaultTolerance1 |
25.1 |
1 |
DefaultTolerance2 |
25.12 |
2 |
DefaultTolerance3 |
25.123 |
3 |
DefaultTolerance4 |
25.1234 |
4 |
DefaultTolerance5 |
25.12345 |
5 |