ExternalRotabReverse

Specifies whether or not to reverse the table’s native direction of rotation in terms of + vs. - position. Internally PC-DMIS assumes that positive rotation is counter-clockwise. In other words, a position of +10 degrees represents 10 degrees of counter-clockwise rotation from the 0 position while a position of –10 represents 10 degrees of clockwise rotation from 0. You should set this value to FALSE (0) if your table natively rotates counter-clockwise. Otherwise set it to 1.

Entry Name: ExternalRotabReverse

Entry Type: Whole Number specifying TRUE (1) or FALSE (0). The default value is 1.