This registry entry specifies the maximum speed for the rotary table (if it is present). Usually, PC-DMIS automatically reads this value from the controller configuration the first time you start the interface, or any time you start the interface when ReadCmmDefaults = TRUE.
For native Leitz systems, you can change the maximum rotary table's velocity with the MaxTableSpeed registry entry.
For I++ interfaces, since there is no option in the Machine Interface Setup dialog box to set the rotary table's maximum speed, you must use the MaxTableSpeed registry entry in PC-DMIS Settings Editor. This is used exclusively for Technology Server version 1.5 for Wetzlar CMMs.
Entry Name: MaxTableSpeed
Entry Type: Whole Number to specify the maximum speed of your rotary table. The default value is dependant on the interface type:
Interface | Default Value |
FDC | 20 |
I++ | 72 |
Leitz | 20 |