SlaveTempSensorNumbers(0-3)

The SlaveTempSensorNumbers values contain a list of one or more sensor numbers to be used for the given axis or part for the slave arm of a dual arm configuration. These values are very important when reading temperatures from the controller because they must correspond to how the sensors are actually configured.

Entry Name: SlaveTempSensorNumbers(0-3)

Entry Type: Character string that specifies the sensor number. The default value is None ( ).

Number Key

Value

Option

0

X Axis

1

Y Axis

2

Z Axis

3

Part

For "manual" mode, these numbers are relatively meaningless, but at least one sensor number must be assigned for each axis and the part.