Bitmapped integer for the following purposes:
Entry Name: SpecialOptions
Entry Types: 0 (Zero) is the default
Bit 1: Force ToolChanger to be checked for all probes - specific to one installation - do not use.
Bit 2: 0 = Accepts the command and always returns OK - 2 = returns error
Bit 4: ScanOnHelix: 0 = Pitch is defined and follows cylinder direction for CW scan direction. 4 = pitch is always along cylinder axis, CW or CCW.
Bit 8: 0 = Leitz protocol CMMM thermal scale compensation is activated in I++ mode. 8 = No scale comp.
Bit 16: 16 = Sets a specific flag for giving a hard coded answer to GetCollisionVolume() - installation specific - do not use.
Bit 32: 32 = Force manual tool change.
Bit 64: 64 = Disables NCSensor internal use. - Development use only for now
Bit 128: 128 = Disables identification of NCSensor. - Development use only for now