At this point, the CAD View displays all measured features. You may want to disable the display of the point IDs in the CAD View.
To disable points IDs:
Select the Edit | Graphic Display Window | Feature Appearance menu item. The Edit Feature Appearance dialog box appears.
Highlight the point features (PNT-PNT9) to select them.
Set the Label Display option to Off.
Click Apply and then OK.
The CAD View should be similar to the one shown below. Notice that the coordinate system origin is in the lower-left corner. X+ is to the right, and Y+ is to the rear.
When you execute the measurement routine up to this point, it establishes the needed alignment for measuring additional features for evaluation.