MaxTableSpeed

This registry entry specifies the maximum speed for the rotary table (if it is present). Usually, PC-DMIS automatically reads this value from the controller configuration the first time you start the interface, or any time you start the interface when ReadCmmDefaults = TRUE.

For native Leitz systems, you can change the maximum rotary table's velocity with the MaxTableSpeed registry entry.

For I++ interfaces, since there is no option in the Machine Interface Setup dialog box to set the rotary table's maximum speed, you must use the MaxTableSpeed registry entry in PC-DMIS Settings Editor. This is used exclusively for Technology Server version 1.5 for Wetzlar CMMs.

Entry Name: MaxTableSpeed

Entry Type: Whole number that specifies the maximum speed of your rotary table. The default value is dependent on the interface type:

Interface Default Value
FDC 20
I++ 72
Leitz 20