PressEndKey

When this registry entry is set to TRUE (1), PC-DMIS waits for you to press the End key before it accepts the last hit taken. This allows you to preview the last hit before you accept it. When this value is set to FALSE, the software does not store the current hit that you take with the jog box in the hit buffer. Instead, it becomes the last hit for the feature, even if you take the hit at the wrong spot.

Entry Name: PressEndKey

Entry Type: Whole number that specifies TRUE (1) or FALSE (0). The default value is 1.