RePierceTolInMM

This registry entry is the current value of the IterateAndRePierceCadOnBestFitAlignmentsMaxLoops registry entry and determines the tolerance value (in MM) to use when the AlignmentIterateRepierce registry entry is enabled. The new nominal point will then be the CAD point closest to the actual feature, provided it is within this tolerance.

Entry Name: RePierceTolInMM

Entry Type: Real number. The default value is 20.

The IterateAndRePierceCadOnBestFitAlignmentsMaxLoops registry entry is used for backwards compatibility with older versions (version 4.3 and earlier).