ExchangeABAxes = True - Allows going from PC-DMIS/RENISHAW A and B angle definitions to ZEISS head angle definitions. To maintain compatibility, the settings for the entries FlipAAxis and FlipBAxis are also set.
FlipAAxis = True - Boolean. True inverts the sign of angle A.
FlipBAxis = True - Boolean. True inverts the sign of angle B.
UseCaaWrist = True - PC-DMIS sends the angle and the stylus numbers to CMM-OS, instead of the configuration file.