AltDoneKey = F1 - This parameter sets the F1 key press to act as the Done key. For example, for MCU LITE which has no "Done" key function.

AltDeleteKey = F2 - This parameter sets the F2 key press to act as the Delete key. For example, for MCU LITE which has no "Delete Last Point" key.

Starting with I++ Client version 2.32, along with AltDoneKey and AltDeleteKey keys, you can define a total of 12 operations with the I++ server jog box. The I++ server can produce the KeyPress:F10 for the F10 key. If you want to assign the F10 key to the EnableProbe command, use the definition KeyPressEnableProbe = F10.

KeyPressCancel = "" - This parameter sets whatever key you enter to function as the Cancel key.

KeyPressDccMeasure = "" - This parameter sets whatever key you enter to function as the DCC Measure key.

KeyPressDelete = "" - This parameter sets whatever key you enter to function as the Delete key.

KeyPressEnableProbe = "" - This parameter sets whatever key you enter to function as the Enable Probe key.

KeyPressEnd = Done - This parameter sets the Done key press to act as the End key.

KeyPressErase = Del - This parameter sets the Del key press to act as the Erase key.

KeyPressExecContinue = "" - This parameter sets whatever key you enter to function as the Exec Continue key.

KeyPressExecStop = "" - This parameter sets whatever key you enter to function as the Exec Stop key.

KeyPressInsertMove = "" - This parameter sets whatever key you enter to function as the Insert Move key.

KeyPressManDcc = "" - This parameter sets whatever key you enter to function as the Man DCC key.