SupportsReadAllTemperatures = True - When this entry is set to True (default), the system implements and uses the ReadAllTemperatures command.
The Technology Server (TS) for the Leitz B5 uses a special implementation of the LEITZ commands. For details, see the CTSServer options in the "Server - Specifics" section.
The Zeiss DME Server supports the UpdateTemperature command. For details, see the ZeissServer options in the "Server - Specifics" section.
UseGetPartTemperature = False - This registry entry is for the Wenzel I++ server without an axis assignment since it doesn't support the ReadAllTemperatures command.
When set to True and SupportsReadAllTemperatures = False, you must use an arbitrary sensor number in the Temperature Compensation Setup dialog box.
When you set UseGetPartTemperature to False (default), you must use the ReadAllTemperatures command and set the correct sensors in the Temperature Compensation Setup dialog box.