Troubleshooting Column Placement

Collisions

Problem: PC-DMIS can't place the specified column because there is a collision with another column in the same fixture. If you continue past the warning message, you can graphically see the colliding columns in the PC-DMIS Graphic Display window.

Resolution: Change the location at which the fixture is held or change the configuration of the module so that the column is no longer in a collision situation.

Out of Machine Volume

Problem: The fixture is outside the usable fixture volume. Generally, this means that if you execute the routine, all or some of the fixture is off the CMM plate. This can generate an error during execution. It can also cause a collision that damages one of the columns or the machine.

Resolution: Change the offsets associated with this fixture. To do this, go to the Machine Orientation area on the Fixture Points tab and change the X offset and Y offsets.