This registry entry allows you to define the default value for the Radius option that PC-DMIS uses when it creates an Auto Square Slot or Notch. Square Slots or Notches aren't always exactly square. They often have radii instead of corners. The Radius value holds a value the size of that radius.
Entry Name: DccRadius
Entry Type: Real Number to specify the radius distance. The default value is 0.
Square Slot - PC-DMIS uses this entry to determine the location of each hit during the measurement of the slot to avoid hitting on the radii.
Notch - PC-DMIS uses hits along the edge opposite the open side to adjust off the radius.