This registry entry lets you specify which PC-DMIS NX layers, by number, to import from the CAD data. You can type an expression that specifies which NX layers to import from the CAD data.
Entry Name: LayerNumbersToImport
Entry Type: Character string that specifies the set of layers to import. The default value is 1-256.
The layers are specified by individual layers, separated by commas, by ranges of layers separated by commas, or by ranges specified with a hyphen before or after a layer number. The following table of examples illustrates some valid formats.
Examples of Set Expression Import Interpretation
Value |
Set of Layers to Import |
1-10, 20-30 |
NX CAD data on layers 1-10 and 20-30 |
1-8 |
NX CAD data on layers 1-8 |
100-256 |
NX CAD data on layers 100-256 |
7 |
NX CAD data on layer 7 |
* or None |
NX CAD data on all layers, 1-256 |