This registry entry specifies the maximum speed for the rotary table (if it is present). Usually, PC-DMIS automatically reads this value from the controller configuration the first time you start the interface, or any time you start the interface when ReadCmmDefaults is set to TRUE.
For native Leitz systems, you can change the maximum rotary table's velocity with the MaxTableSpeed registry entry.
For I++ interfaces, since there is no option in the Machine Interface Setup dialog box to set the rotary table's maximum speed, you must use the MaxTableSpeed registry entry in PC-DMIS Settings Editor. This is used exclusively for Technology Server version 1.5 for Wetzlar CMMs.
Entry Name: MaxTableSpeed
Entry Type: Whole number that specifies the maximum speed of your rotary table. The default value is dependent on the interface type:
Interface | Default Value |
FDC | 20 |
I++ | 72 |
Leitz | 20 |