PC-DMIS 2022.1 Object Library
GetFilterParams Method
See Also  Send Topic Feedback | See Object Hierarchy Chart
dCutAxisLocation
Used for Manual scans with Filter property set to BSF_BODYAXISDISTANCE.
nAxis
Required Long variable that gets the cut axis. Returns non-zero only for axis filters. For axis filters, 0 means the X axis, 1 means the Y-axis, and 2 means the Z-axis.
dMaxIncrement
Required Double variable that gets the maximum increment. For fixed-length filters, this is simply the fixed increment. This is the Time delta values in case the filter is BSF_TIME_DELTA or BSF_VARIABLEDISTANCE for Manual scans.
dMinIncrement
Required Double variable that gets the minimum increment for Variable Distance Filters. This is the Drop Point distance when a Manual scan is being used with the filter set to BSF_VARIABLEDISTANCE.
dMaxAngle
Required Double variable that gets the maximum angle used in Variable Distance Filters.
dMinAngle
Required Double variable that gets the minimum angle used in Variable Distance Filters.
PCDLRN ActiveX DLL > Scan Object : GetFilterParams Method

Glossary Item Box

Description

Gets parameters used in filtering of scan data

Syntax

Visual Basic
Public Function GetFilterParams( _
   ByRef dCutAxisLocation As Double, _
   ByRef nAxis As Long, _
   ByRef dMaxIncrement As Double, _
   ByRef dMinIncrement As Double, _
   ByRef dMaxAngle As Double, _
   ByRef dMinAngle As Double _
) As Boolean

Parameters

dCutAxisLocation
Used for Manual scans with Filter property set to BSF_BODYAXISDISTANCE.
nAxis
Required Long variable that gets the cut axis. Returns non-zero only for axis filters. For axis filters, 0 means the X axis, 1 means the Y-axis, and 2 means the Z-axis.
dMaxIncrement
Required Double variable that gets the maximum increment. For fixed-length filters, this is simply the fixed increment. This is the Time delta values in case the filter is BSF_TIME_DELTA or BSF_VARIABLEDISTANCE for Manual scans.
dMinIncrement
Required Double variable that gets the minimum increment for Variable Distance Filters. This is the Drop Point distance when a Manual scan is being used with the filter set to BSF_VARIABLEDISTANCE.
dMaxAngle
Required Double variable that gets the maximum angle used in Variable Distance Filters.
dMinAngle
Required Double variable that gets the minimum angle used in Variable Distance Filters.

Return Type

Boolean value.

Remarks

 

Filter

GetFilterParams (dCutAxisLocation, nAxis, dMaxIncrement, dMinIncrement, dMaxAngle, dMinAngle)

Distance

,,dMaxIncrement

BodyAxisDistance (DCC)

,nAxis, dMaxIncrement

BodyAxisDistance (Manual)

NCutLocation,nAxis

Time

,,dMaxIncrement

VariableDistance

,,dMaxIncrement, dMinIncrement, dMaxAngle, dMinAngle

 

See Also

Copyright © 2022. Hexagon Manufacturing Intelligence – Metrology Software, Inc. All Rights Reserved.