LaserLineFilterPointsSpacing

When analyzing the incoming scan data and reducing the number of points, this entry defines the maximum distance between two consecutive points. When set to 0, no reduction is done. This value should be less than 1/3 of the LaserLineHoleLengthMM.

Entry Name: LaserLineFilterPointsSpacing

Entry Type: All positive Real numbers. The default value is 0.25.