SetScanParams Method
Description
Sets scan parameters (used in StartScan block)
Syntax
Visual Basic |
---|
Public Sub SetScanParams( _ ByVal incr As Double, _ ByVal AXIS As PAXISTYPE, _ ByVal max_incr As Double, _ ByVal min_incr As Double, _ ByVal MAX_ANGLE As Double, _ ByVal MIN_ANGLE As Double, _ ByVal delta As Double, _ ByVal DISTANCE As Double, _ ByVal incr2 As Double, _ ByVal axis2 As PAXISTYPE, _ ByVal surf_thickness As Double _ ) |
Parameters
- incr
- Increment value for LINE, BODY, and CUTAXIS scan techniques. Optional.
- AXIS
Axis for BODY and CUTAXIS scan techniques. PCD_XAXIS, PCD_YAXIS, PCD_ZAXIS. Optional.Value Description PCD_XAXIS Mirrors the virtual machine's X axis. PCD_YAXIS Mirrors the virtual machine's Y axis. PCD_ZAXIS Mirrors the virtual machine's Z axis. - max_incr
- For VARIABLE scan techniques. Optional.
- min_incr
- For VARIABLE scan techniques. Optional.
- MAX_ANGLE
- For VARIABLE scan techniques. Optional.
- MIN_ANGLE
- For VARIABLE scan techniques. Optional.
- delta
- Distance delta for FIXED_DELTA scans, time delta for VARIABLE_DELTA and TIME_DELTA scans. Optional.
- DISTANCE
- Drop point distance for VARIABLE_DELTA scan, distance for CUTAXIS scan. Optional.
- incr2
- Increment value in second direction for a patch scan. Optional.
- axis2
Second axis value for a patch scan (BODY scan technique only). Optional.Value Description PCD_XAXIS Mirrors the virtual machine's X axis. PCD_YAXIS Mirrors the virtual machine's Y axis. PCD_ZAXIS Mirrors the virtual machine's Z axis. - surf_thickness
- Surface thickness used to offset centroid calculation if necessary. Optional.
See Also