Suppose you have these three probes configurations:
PROBE_01 |
PROBE_02 |
PROBE_03 |
QuickConnect AutoJoint |
QuickConnect AutoJoint |
QuickConnect AutoJoint |
TP2 |
TP20 |
TP20 |
3mmx10mm stylus |
2mmx10mm stylus |
4mmx20mm stylus |
The ACR1 will switch between the TP2 and the TP20 probes. The MCR20 will switch between the styli associated with the TP20 probe system(s).
A typical port definition might look like this:
ACR1 |
MCR20 |
Port 1 |
Port 2 |
Probe_01 |
Probe_02 |
Probe_03 |
In operation, suppose the system is using PROBE_01 and it needs to switch to PROBE_02. The system would:
Pause the measurement routine.
Travel to the clearance location for the ACR1.
Return the currently loaded probe to port #1 of the ACR1.
Move to port #2 of the ACR1 and pick up the TP20 body for PROBE_02.
Use the respective Safety/Clearance points and move to the MCR20.
Move into port #1 of the MCR20 to attach the stylus adapter with the desired stylus.
Return to the MCR20’s Clearance point.
Continue with the measurement routine.
Suppose after measuring some features, the system then needs to use PROBE_03. The system would:
Pause the measurement process.
Travel to the clearance location for the MCR20.
Move into port #1 to drop off PROBE_02’s stylus.
Travel out, over, and into port #3 to pick up the stylus required for PROBE_03.
Travel to the clearance location.
Continue with the measurement routine.
Now, suppose the system needs to switch from PROBE_03 (the TP20 with the 4mmx20mm stylus) back to Probe_01 (the TP2 with the 3mmx10mm stylus). The system would:
Pause the measurement routine.
Move to the clearance point for the MCR20.
Go into port #2 and drop off the stylus assembly.
Return to the MCR20’s clearance location
Move to the ACR1’s clearance location.
Go into port #2 to drop off the TP20 assembly.