Q-DAS Configurator supports the list of K-fields in the following table:
| Key | Type | Length | Field Name |
| K0001 | F | 22 | Measured Value |
| K0002 | I5 | 5 | Attribute |
| K0004 | D | --- | Time |
| K0005 | S | --- | Event |
| K0006 | AN | 14 | Batch Number |
| K0007 | I10 | 10 | Cavity Number |
| K0008 | I10 | 10 | Operator Name |
| K0009 | AN | 255 | Text |
| K0010 | I10 | 10 | Machine Number |
| K0011 | S | --- | Process Parameter |
| K0012 | I10 | 10 | Gage Number |
| K0013 | I5 | 5 | Process Parameter Value |
| K0014 | AN | 40 | Part ID Number |
| K0015 | I5 | 5 | Reason for Test |
| K0016 | AN | 30 | Production Number |
| K0017 | AN | 30 | Workpiece Fixture Number |
| K0020 | I5 | 5 | Subgroup Size |
| K0021 | I5 | 5 | Number of Errors |
| K0053 | AN | 20 | Order |
| K0054 | AN | 30 | K0054 |
| K0055 | AN | 30 | K0055 |
| K0056 | AN | 30 | K0056 |
| K0057 | AN | 30 | K0057 |
| K0058 | AN | 30 | K0058 |
| K0059 | AN | 30 | K0059 |
| K0060 | AN | 30 | K0060 |
| K0061 | I10 | 10 | K0061 |
| K0062 | I10 | 10 | K0062 |
| K0063 | I10 | 10 | K0063 |
| K0080 | AN | 64 | Subgroup ID |
| K0081 | I5 | 5 | Value Position in Subgroup |
| K0100 | I5 | 5 | Total Number of Characteristics in File |
| K1001 | AN | 30 | Part Number |
| K1002 | AN | 80 | Part Description |
| K1003 | AN | 20 | Part Abbreviation |
| K1004 | AN | 20 | Part Amendment Status |
| K1005 | AN | 40 | Product |
| K1007 | AN | 20 | Abbreviation Part Number |
| K1008 | AN | 20 | Part Type |
| K1009 | AN | 20 | Part Code |
| K1010 | I3 | 3 | Control Item |
| K1011 | AN | 20 | Version |
| K1014 | AN | 20 | Part Identification |
| K1021 | AN | 20 | Manufacturer Number Text |
| K1022 | AN | 80 | Manufacturer Name |
| K1031 | AN | 20 | Material Number Text |
| K1032 | AN | 80 | Material Description |
| K1041 | AN | 30 | Drawing Number |
| K1042 | AN | 20 | Drawing Amendment |
| K1043 | AN | 80 | Drawing Index |
| K1052 | AN | 80 | Contractor Description |
| K1053 | AN | 40 | Contract |
| K1061 | AN | 20 | Customer Number Text |
| K1062 | AN | 40 | Customer Description |
| K1071 | AN | 20 | Supplier Number Text |
| K1072 | AN | 40 | Supplier Name |
| K1081 | AN | 24 | Machine Number |
| K1082 | AN | 40 | Machine Description |
| K1083 | I5 | 5 | Machine Number |
| K1085 | AN | 40 | Machine Location |
| K1086 | AN | 40 | Work Cycle / Operation Number |
| K1087 | AN | 40 | Production Cycle Description |
| K1100 | AN | 40 | Plant Sector |
| K1101 | AN | 40 | Department |
| K1102 | AN | 40 | Workshop / Sector |
| K1103 | AN | 40 | Cost Center |
| K1104 | AN | 20 | Shift |
| K1110 | AN | 20 | Order Number |
| K1111 | AN | 20 | Goods Received Number |
| K1201 | AN | 24 | Test Facility Number |
| K1202 | AN | 40 | Test Facility Description |
| K1203 | AN | 80 | Reason for Test |
| K1206 | AN | 40 | Test Location |
| K1209 | AN | 20 | Inspection Type |
| K1210 | I5 | 5 | Measurement Type |
| K1221 | AN | 20 | Inspector Number (Text) |
| K1222 | AN | 40 | Inspector Name |
| K1230 | AN | 40 | Gage Room |
| K1231 | AN | 20 | Measuring Program Number |
| K1232 | AN | 20 | Measuring Program Version |
| K1302 | AN | 40 | Test Batch |
| K1303 | AN | 40 | Plant |
| K1311 | AN | 40 | Production Order |
| K1341 | AN | 20 | Test Plan Number Text |
| K1343 | D | 20 | Test Plan Development Date |
| K1344 | AN | 40 | Test Plan Developer |
| K1802 | AN | 255 | User Field Content 1 |
| K1812 | AN | 255 | User Field Content 2 |
| K1822 | AN | 255 | User Field Content 3 |
| K1832 | AN | 255 | User Field Content 4 |
| K1842 | AN | 255 | User Field Content 5 |
| K1852 | AN | 255 | User Field Content 6 |
| K1860 | AN | 50 | User Field Description 7 |
| K1861 | AN | 1 | User Field Type 7 |
| K1862 | AN | 255 | User Field Content 7 |
| K1900 | AN | 255 | Remark |
| K1997 | AN | --- | Parts GUID |
| K2001 | AN | 20 | Characteristic Number |
| K2002 | AN | 80 | Characteristic Description |
| K2003 | AN | 20 | Characteristic Abbreviation |
| K2004 | I5 | 5 | Characteristic Type |
| K2005 | I5 | 5 | Characteristics Class |
| K2006 | I5 | 5 | Control Item |
| K2007 | I5 | 5 | Control Type |
| K2008 | I5 | 5 | Group Type |
| K2009 | I5 | 5 | Measured Quantity |
| K2015 | I3 | 3 | Tool Wear Type |
| K2016 | I3 | 3 | 100% Measurement |
| K2020 | I3 | 3 | Material Condition |
| K2022 | I5 | 5 | Decimal Places |
| K2030 | I5 | 5 | Group Number |
| K2031 | I5 | 5 | Group Element Number |
| K2043 | AN | 40 | Recording Device Name |
| K2060 | I5 | 5 | Events Catalog |
| K2061 | I5 | 5 | Process Parameter Catalog |
| K2062 | I5 | 5 | Cavity Catalog |
| K2063 | I5 | 5 | Machine Catalog |
| K2064 | I5 | 5 | Gage Catalog |
| K2065 | I5 | 5 | Operator Catalog |
| K2066 | I5 | 5 | Subcatalog K0061 |
| K2067 | I5 | 5 | Subcatalog K0062 |
| K2068 | I5 | 5 | Subcatalog K0063 |
| K2092 | AN | 50 | Characteristic Text |
| K2093 | AN | 80 | Processing Status |
| K2095 | AN | 40 | Element Code |
| K2096 | AN | 20 | Element Index |
| K2097 | AN | 50 | Element Text |
| K2100 | F | 22 | Target Value |
| K2101 | F | 22 | Nominal Value |
| K2110 | F | 22 | Lower Specification Limit |
| K2111 | F | 22 | Upper Specification Limit |
| K2112 | F | 22 | Lower Allowance |
| K2113 | F | 22 | Upper Allowance |
| K2114 | F | 22 | Lower Scrap Limit |
| K2115 | F | 22 | Upper Scrap Limit |
| K2120 | I3 | 3 | Lower Limit Value |
| K2121 | I3 | 3 | Upper Limit Value |
| K2130 | F | 22 | Lower Plausibility Limit |
| K2131 | F | 22 | Upper Plausibility Limit |
| K2142 | AN | 20 | Unit |
| K2202 | I3 | 3 | Evaluation Type |
| K2203 | I3 | 3 | Car Body Mode |
| K2205 | I5 | 5 | Number of Parts |
| K2211 | AN | 40 | Master Number |
| K2212 | AN | 40 | Master Description |
| K2213 | F | 22 | Standard Actual Value |
| K2216 | AN | 20 | Master - Serial Number |
| K2220 | I5 | 5 | Number of Operators |
| K2221 | I5 | 5 | Number of Trials |
| K2222 | I5 | 5 | Number of Reference Measurements |
| K2281 | AN | 40 | Calibrating Part - Center Number |
| K2301 | AN | 20 | Machine Number |
| K2302 | AN | 40 | Machine Description |
| K2303 | AN | 40 | Department / Cost center |
| K2311 | AN | 20 | Production Type |
| K2312 | AN | 40 | Production Type Description |
| K2320 | AN | 20 | Contract Number |
| K2401 | AN | 40 | Gage Number |
| K2402 | AN | 80 | Gage Description |
| K2403 | AN | 20 | Gage Group |
| K2404 | F | 22 | Gage Resolution |
| K2406 | AN | 40 | Gage Manufacturer |
| K2407 | AN | 20 | SPC Device Number |
| K2408 | AN | 20 | SPC Device Manufacturer |
| K2409 | AN | 20 | SPC Device Type |
| K2410 | AN | 40 | Test Location |
| K2411 | D | 40 | Test Begin |
| K2415 | AN | 20 | Gage Serial Number |
| K2434 | I5 | 5 | Proof of Process Capability |
| K2440 | AN | 40 | Assembly Component |
| K2505 | AN | 20 | View Description |
| K2506 | I3 | 3 | Sheet Number |
| K2630 | F | 22 | Calibration Uncertainty |
| K2802 | AN | 255 | Tool Number / Tool Name |
| K2810 | AN | 50 | Lower Reaction Limit |
| K2812 | AN | 255 | Experience Value |
| K2820 | AN | 50 | Upper Reaction Limit |
| K2822 | AN | 255 | Floating Average Factor |
| K2830 | AN | 50 | Compensation on Reject |
| K2832 | AN | 255 | No Correction Range |
| K2840 | AN | 50 | Calculation Direction |
| K2842 | AN | 255 | Maximum Compensation |
| K2850 | AN | 50 | Tool Geometry |
| K2852 | AN | 255 | Reference Geometry |
| K2860 | AN | 50 | Tool Compensation |
| K2862 | AN | 255 | Action in Case of Tool Violation |
| K2870 | AN | 50 | Tool Wear Limit |
| K2872 | AN | 255 | Alpha Compensation |
| K2880 | AN | 50 | Spindle / Head Number / Name |
| K2882 | AN | 255 | Roughing Tool Number / Name |
| K2890 | AN | 50 | Add Value for Rougher |
| K2892 | AN | 255 | Part Skip Value |
| K2900 | AN | 255 | Remark |
| K2991 | AN | 255 | PCD ID |
| K5001 | AN | 30 | Group Number (Text) |
| K5002 | AN | 80 | Group Description |
| K5101 | I5 | 5 | Part as Part of a Group |
| K5102 | I5 | 5 | Characteristic as Part of a Group |
| K5103 | I5 | 5 | Group as Part of a Group |
| K5111 | I5 | 5 | Parts Group |
| K5112 | I5 | 5 | Characteristics Group |
| K5113 | I5 | 5 | Group Element |
| K8010 | S | --- | Chart Type (Location) |
| K8011 | F | 22 | Central Position (Location) |
| K8012 | F | 22 | Lower Control Limit (Location) |
| K8013 | F | 22 | Upper Control Limit (Location) |
| K8014 | F | 22 | Lower Warning Limit (Location) |
| K8015 | F | 22 | Upper Warning Limit (Location) |
| K8110 | S | --- | Chart Type (Variation) |
| K8111 | F | 22 | Central Position (Variation) |
| K8112 | F | 22 | Lower Control Limit (Variation) |
| K8113 | F | 22 | Upper Control Limit (Variation) |
| K8114 | F | 22 | Lower Warning Limit (Variation) |
| K8115 | F | 22 | Upper Warning Limit (Variation) |
| K8500 | I5 | 5 | Subgroup Size |
| K8501 | I3 | 3 | Subgroup Type |
| K8502 | AN | 40 | Subgroup Frequency |
| K8503 | I3 | 3 | Stable Subgroup Size |
| K8504 | I5 | 5 | Subgroup Incidence |
| K8505 | I5 | 5 | Number of Parts (ELS) |
| K8520 | F | 22 | Required Cp Value |
| K8521 | F | 22 | Required Cpk Value |
| K8522 | F | 22 | Fixed Cp Value |
| K8523 | F | 22 | Fixed Cpk Value |
| K8600 | I3 | 3 | Correction Strategy |
| K8610 | F | 22 | Lower Correction Limit |
| K8611 | F | 22 | Upper Correction Limit |
| K8612 | I3 | 3 | Buffer Size |
| K8613 | F | 22 | Correction Target Value |