Inserting Q-DAS Tracefields

Select Insert | Statistics Command | Q-DAS Tracefields to insert the Q-DAS tracefields. This option inserts the tracefields for K-fields whose "Value From" properties are set to "TRACE" in the Setup K-Field Configuration window of the Q-DAS Configurator.

Q-DAS tracefields help you create measurement routines that support Q-DAS statistical software. For information on the Q-DAS Configurator, see the Q-DAS Configurator documentation.

Before you insert Q-DAS tracefields, you need to create a STATS/ON,Q-DAS,DFQ command. For information, see "Sending Statistics to a Q-DAS Database".

After you insert Q-DAS tracefields, if you update the Q-DAS configuration file (<name>.qdascfg.xml), you must re-insert the Q-DAS tracefields.

Here's an example of some Q-DAS tracefields in the Edit window:

QDAS_TRACEFIELDS=GROUP/SHOWALLPARAMS=No

EXECUTION CONTROL=AS MARKED

ENDGROUP/ID=QDAS_TRACEFIELDS

 

To expand the group, you can change SHOWALLPARAMS from No to Yes.

QDAS_TRACEFIELDS=GROUP/SHOWALLPARAMS=YES

EXECUTION CONTROL=AS MARKED

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Batch Number ; K0006 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Cavity Number ; K0007 : (1) [N1001] [Group 1]

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Operator Name ; K0008 : (1) [P001] [Operator 1]

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Machine Number ; K0010 : (1) [M001] [Machine 1]

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Gage Number ; K0012 : (1) [PM001] [CMM 1] [CMM Grp. 1]

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Part ID Number ; K0014 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Order ; K0053 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Part Number ; K1001 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Contract ; K1053 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Work Cycle / Operation Number ; K1086 :

TRACEFIELD/DISPLAY=YES,REPORT=NO,DISPLAY MESSAGE=Remark ; K1900 :

ENDGROUP/ID=QDAS_TRACEFIELDS