Converting from the Tech80 to the Manual CMM Interface

When you convert from the Tech80 interface to the Manual CMM interface, you must do the following:

  1. Add the Manual Interface option to your license:

LMS

Portlock

The dll's for the interfaces are:

When you have multiple interfaces, or you have the All Interfaces option set on your license, service pack updates do not install either of these dll files

  1. Copy the drivers as you would for the Tech80 interface:

Source: C:\Program Files\Hexagon\CSI 64 BIT

Destination: C:\Program Files\Hexagon\<PC-DMIS folder>

Where <PC-DMIS folder> is the root of the PC-DMIS installation location.

The drivers include:

* The "xxx" denotes the language code for each language-specific dll file. The number of languages you included when you installed the interface is the number versions of this dll file.

  1. In a text editor, open the GMS.XML file located in the root of the PC-DMIS install location and edit the settings. Locate the General section and make the necessary changes.

GMS.XML file General settings changes

In the Interfaces section, locate the Simulator Interface section and add comment delimiters.

GMS.XML Simulator interface settings changes

  1. Open the GMSXNPCI.XML file located in the root of the PC-DMIS installation folder. Modify what was previously called the Stretch and Resolution settings.

GMSXNPCI.XML settings changes

Depending on how your folder permissions are set, in order to edit the files, you might need to copy them out of PC-DMIS directory into a temporary folder. When done, save the changes and then copy the files back into the PC-DMIS directory.

  1. Change the VolComp value in the Settings Editor application to 14.

You only need to set this Settings Editor value for PC-DMIS version 2022.1 and later. You can use the Tech80 settings for PC-DMIS versions prior to version PC-DMIS 2021.2.

Related Topics:

Tech80 Interface

More:

Manual CMM Interface