zeiss.dll Version 1.91

This version of the zeiss.dll fixes the problem with manual probing on the HSS probe head.

  1. Added a new value for CALC_VECTOR_TYPE Hardware (3). For details, see "zeiss.dll Version 1.76n".

CALCVECTOR_TYPE = [0123]

Example:

VAST_PROBE_TYPE

CALCVECTOR_TYPE=3

You can also trigger this option on by adding HARDWARE_VECTOR_IN_MANUAL=1 in the configuration file.

Example:

VAST_PROBE_TYPE

HARDWARE_VECTOR_IN_MANUAL=1

  1. Added the newly-documented option MANUAL_PROBE_MODE

MANUAL_PROBE_MODE = 1

Use this option to downgrade HSS or VAST probe head into MT probe head probing. This is equivalent to an analog probe head on 8-bit controllers.

Instead of a sequence of commands M21 and M22, PC-DMIS sends the sequence with clamping to the controller. For example, M21XY and M22Z.