BUNDLE ALIGN/ID = 1,SHOW DETAIL = TOG1
FIT OPTIONS/TYPE = TOG2,BALANCED = TOG3,BLUNDER ANALYSIS = TOG4
MEASURE FEATURES/PNT1,PNT2,PNT3,
BUNDLED FEATURES/
STATION = 1,PNT1,PNT2,PNT3,PNT4,
STATION = 2,PNT1,PNT2,PNT3,,
STATION = 3,PNT1,PNT2,PNT4,,
STATION =
ID: This field provides the active station number. This is the station from which "Bundle Alignment Features" will be measured.
TOG1 (SHOW DETAIL = YES/NO): When this value is set to YES, a detailed listing of the Bundle Alignment appears in the Edit window. By default, this value is set to NO, which does not display the FIT OPTIONS.
TOG2 (FIT OPTIONS/TYPE = type): Choose one of four available Fit Options: NORMAL, POINTS AND STATIONS FIXED, RECALCULATE ALL, and STATIONS FIXED. See "Setting Fit Options".
TOG3 (BALANCED = OFF/ON): When this value is set to ON, a balanced network solution is used. By default, this value is set to OFF. See "Setting Fit Options".
TOG4 (BLUNDER ANALYSIS = OFF/ON): When this value is set to ON, Blunder Analysis is used. By default, this value is set to OFF. See "Setting Fit Options".
MEASURE FEATURES: Lists the "Bundle Alignment Features" that will be measured for the active station number.
BUNDLED FEATURES: Lists the stations and "Bundle Alignment Features" that are included in the Bundle Alignment computations.