Sub-Catalog data Area

When you open the Q-DAS Configurator application, the Sub-Catalog data area has no data. To use the sub-catalog, select File | Create Q-DAS Data File so that that Q-DAS Configurator pulls information from the open measurement routine into the area.

The measurement routine's sub-catalog data appears in the Sub-Catalog data area.

This area lets you select the sub-catalog if your catalog file defines the sub-catalog for the corresponding K-field. Initially, it displays the default sub-catalog. For more information on the sub-catalog, see the Q-DAS documentation.

When you select the sub-catalog, during the execution of a measurement routine, the tracefield for the K-field displays only those values for selection that are in the list of this sub-catalog. If you define any entry as obsolete in the catalog file, the list does not display the value.

You can position your mouse pointer over any K-field value to display a tooltip that shows the corresponding K-field's name and number.

Suppose for Key K2062, the tooltip displays Catalog for K0010 (Machine Number). This indicates that K2062 records the value of the sub-catalog for K0010, which is for a machine number.

Following is the list of catalog type K-fields as defined in AQDEF standard documentation along with their corresponding catalog, sub-catalog, and obsolete entries:

K-field Name Catalog Sub-Catalog number Obsolete entries
K0005 Events K4220 K2060 K4721
K0007 Cavity K4250 K2062 K4751
K0008 Operator K4090 K2065 K4591
K0010 Machine K4060 K2063 K4561
K0011 Process Parameter K4240 K2061 K4741
K0012 Gage K4070 K2064 K4571
K0061 Custom K4270 K2066 K4771
K0062 Custom K4280 K2067 K4781
K0063 Custom K4290 K2068 K4791