Send Topic Feedback | See Object Hierarchy Chart
PC-DMIS 2023.2 Object Library
PCDLRN ActiveX DLL : BSCANMETH_ENUM Enumeration
BSCANMETH_ENUM Enumeration
Members
MemberValueDescription
BSCANMETH_ANGLE100075 
BSCANMETH_CENTER100140Finds a Low Point on a surface.
BSCANMETH_CIRCLE100125Scans around a circle in a high speed, continuous contact mode.
BSCANMETH_CLOSE100510This method will scan the surface along a line. This procedure uses the starting and ending point for the line and also includes a direction point. The probe will always remain within the cut plane while doing the scan.The scan will start and finish at the same Point. This is valid oly for DCC scans.
BSCANMETH_CYLINDER100130Scans around a cylinder in a high speed, continuous contact mode.
BSCANMETH_EDGE100050Scans the Edge of the Surface in a Touch Trigger mode.
BSCANMETH_FREEFORM100555 
BSCANMETH_GRID100560 
BSCANMETH_LINEAR100010Scans the surface along a line. This procedure uses the starting and ending point for the line, and also includes a direction point. The probe will always remain within the cut plane while doing the scan.
BSCANMETH_MANUAL_FIXED_PROBE100610This is valid only for Manual scans and will allow you to use a Hard Probe to take Manual hits.
BSCANMETH_MANUAL_TTP100600This is valid only for Manual scans and will allow you to use a Touch Trigger Probe to take Manual hits.
BSCANMETH_OPEN100500This method will scan the surface along a line. This procedure uses the starting and ending point for the line and also includes a direction point. The probe will always remain within the cut plane while doing the scan. This is valid oly for DCC scans.
BSCANMETH_PATCH100520This method will scan the surface in multiple rows depending on the Boundary Points. This is valid oly for DCC scans.
BSCANMETH_PERIMETER100100 
BSCANMETH_ROTARY100545 
BSCANMETH_STRAIGHTLINE100135Scans a straight line in a high speed, continuous contact mode.
BSCANMETH_UV100530