Send Topic Feedback | See Object Hierarchy Chart
PC-DMIS 2023.2 Object Library
Overview 
PCDLRN ActiveX DLL : QualificationSettings Object
QualificationSettings Object Members
Public Methods
This method returns a tool object.
Required expression that evaluates to a QualificationSettings object.
Public Properties

This determines whether or not a map should be created or replaced. Read/Write.

This determines the ending A angle to use during qualification.

This determines the End Angle to use on the qualification tool.

This determines the ending B angle to use during qualification.
C Angle End Value
This determines the type of calibration action to take.

This determines the angle increment to use for the A angle during qualification.

This determines the angle increment to for the B angle during qualification.

C Angle Increment Value

This determines the Calibration Mode. Either DCC or Manual.

This determines the speed the probe moves during calibration.

This determines the number of hits to take around the calibration tool.

This determines the number of levels that to use in the calibration process. PC-DMIS divides the number of hits by the number of levels to determine how many hits will be taken on each level of the qualification tool.

This indicates whether angle A or B for a PHS system receives priority during the calibration process. TRUE means Angle A gets priority. FALSE means Angle B gets priority.

For PHS systems, this determines the PHS tolerance value.

This determines the Prehit distance to use during calibration.

This determines whether or not you'll calibrate the shank of the probe as well.

This determines the number of hits used to measure the shank.

Shank Offset for calibration

This determines the starting A angle to use during qualification.

This determines the Start Angle to use on the qualification tool.

This determines the starting B angle to use during qualification.
C Angle Start Value

This indicates whether a tool has moved or not or if the user should be asked.

This indicates whether or not the tool is located on a rotary table.

This determines the I value for the Tool Override's IJK vector.
This determines the J value for the Tool Override's IJK vector.
This determines the K value for the Tool Override's IJK vector.
This determines the Touch Speed to use during calibration.

This determines whether End Angle, Start Angle, and NumLevels are used in the calibration process, or if they're ignored.

This determines whether or not the calibration order is user defined.

See Also