Setting Up a Machine

Before using NC Gage, you must use the Config Tool to configure various machine-related settings for proper operation. This includes connection parameters, kinematic parameters, motion parameters, various macros and M-code settings etc. After you complete these configuration settings, you need to use the Config Tool to generate the machine's macros.

Steps to Setup a Machine

Step

Description

1

Open the Config Tool dialog box. For details, see "Starting the Config Tool".

2

To configure the controller, select the General tab. For details, see "Configuring Items on the General Tab".

3

Press the Read Machine button to read out the machine parameters.

4

Select the [Parameters] tab and set the values there

5

Select the [Axis Setup] tab to configure the kinematics and axis info

6

Select the [Probe] tab and verify the probe macros

7

Press <Save Configuration> to save the data

8

Press <Generate Macro Program> to create the necessary macros

9

Press <Exit> to exit the Config Tool